Large Power Tariff

This tariff is available to all customers receiving supply at primary voltage (i.e. customer-owned transformer). The associated charges are as follows: 

Customer Charge

This applies to each electricity service under this tariff for the fixed costs of providing service, including service installation, meter reading, billing and customer services.

$943.50 / month + VAT

 

Demand Charge

This applies to each electricity service under this tariff for the costs associated with the generating facilities, transmission and distribution lines, substations, transformers and other facilities required to meet individual and combined customer peak demand.

$27.65 / kVA of Billing Demand + VAT

 

Note: In cases where a customer's transformer may fail, or otherwise be unavailable, the Company may provide a transformer on a temporary basis for an additional charge as set out in the Schedule of Service Charges.

 

Base Energy Charge

This applies to each electricity service under this tariff for the variable energy costs associated with the provision of this service, except for the cost of fuel.

All kWh @ $0.1170 / kWh + VAT

 

Fuel Charge

This applies to each electricity service under this tariff for the cost of fuel associated with the provision of this service.

All kWh @ the Fuel Clause Adjustment (cents/kWh) + VAT

 

The Fuel Clause Adjustment is calculated according to the Fuel Clause approved by the Fair Trading Commission and may vary from month to month.

 

Metering on Low Voltage side

Normally the usage for customers under this tariff will be metered on the high voltage side of their transformer. However, under special circumstances, at the Company’s discretion, their usage may be metered on the low voltage side of the transformer. On these occasions, the Company shall increase the billing demand and energy consumed by a loss factor for the calculation of the demand, base energy and fuel charges to account for losses incurred in the customer’s transformer.

 

Minimum Bill 

The minimum bill shall be the billing demand charge plus the customer charge.

 

Billing Demand

(a) Customers connected under this rate shall be metered as to demand and the billing demand shall be the maximum measured demand of the current month or 50 kVA, whichever is greater. The measured demand may be measured in either kW or kVA at the option of the Company depending upon the character of the service. If the demand is measured in kW then the maximum kW reading shall be divided by a correction factor of 0.85 for conversion to kVA for billing purposes.

 

(b) The Company shall reserve the right to assess the billing demand in cases where an accurate demand reading cannot be obtained, for example, due to the inaccessibility of the meter or a demand seal being broken. In these cases, the demand will be assessed using the best estimate of the customer’s kWh/kVA ratio and energy usage for the period. These will normally be determined using an average of the previous three months of the customer’s billing information.

 

(c) The Company shall reserve the right to assess the billing demand based on a connected load for installations with high momentary demands including lifts, cranes, X-ray equipment and welders.

 

(d) For customers with a contracted demand, the billing demand shall be the higher of (a) or (b) or the contracted demand.

 

Type of Service

Under this tariff, the Company will supply three-phase alternating current electricity at 50 Hz, and one of the nominal primary voltages specified in the latest revision of the Company’s booklet entitled “Information and Requirements Covering Installation of Electric Services and Meters”.

 

Conditions of Service

This tariff is available for customers with a billing demand of not less than 50 kVA. No service may be transmitted from a customer to another premises without the express written prior consent of the Company.

 

General Provisions 

When two or more rates are available for certain classes of service, the choice of such rates rests with the customer. The Company will at any time, upon request, advise any customer as to the rate best suited to existing or anticipated service requirements, as defined by the customer. The Company does not assume responsibility for the selection of such rate. A customer, having selected a rate, may not change to another rate within a 12-month period unless there is a substantial change in the character or conditions of the service. In the case of a new service, customers will be given reasonable opportunity to determine their service requirements before selecting their preferred rate.

 

Terms of Service 

Not less than one year.

 

Rules and Regulations 

Service under this schedule is subject to the orders of the Fair Trading Commission and the latest publication of the “Information and Requirements Covering Installation of Electric Services and Meters”. In case of a difference of interpretation between any provision of this schedule and the “Information and Requirements Covering Installation of Electric Services and Meters” booklet, the provision of this schedule shall apply. A bill calculated under this tariff is subject to change under the provisions of such applicable rider(s) as may be approved and/or amended by the Fair Trading Commission.

           